Product Details
Clack WS2CI Filter, Timer Controlled Valve, 2″
Clack introduced its first line of residential control valves. The goal was to design a family of control valves for the water treatment professional that covered the greatest range of applications while having the greatest commonality of parts. All Clack valves incorporate patented* “stack technology” and feature state-of-the-art electronics and programming software.
Description
Product Features
- 2” Top mount control valve suited for commercial/industrial applications
- Epoxy coated lead-free brass valve body*
- Economical stainless steel optional meter assembly
- The service flow rate of 435 lpm (26.1 m3/h) (115 GPM), backwash 303 lpm (18.2 m3/h) (80 GPM)
- Solid state microprocessor with easy access to front panel settings
- Front panel display for time of day, days until next regeneration, volume remaining, current flow rate, and total volume used (Totalizator)
- Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed, or pressure differential
- The optional double backwash feature offers optimum regeneration, cleaning ability, and efficiency
- Fully adjustable cycle times with 6-cycle control deliver controlled backwash, downflow bringing or up flow brining, slow rinse, second backwash, fast rinse, refill and downflow service
- Coin Cell Lithium battery backup with an 8-hour carry over
- 12-volt output AC Adapter provides safe and easy installation
- Post-treatment water regenerate refill
- 24 Hour Clock
- Reliable and proven DC drive
- Patented one-piece expanding seal spacer stack assembly U.S. Patent 6,402,944
- Patented linearly reciprocating piston operation U.S. Patent 6,444,127
Inlet/Outlet Fittings
|
2” Female BSPT or NPT
|
Cycles
|
up to 6
|
Valve Material
|
Noryl (1) or equivalent
|
Regeneration
|
downflow
|
Flow Rate
|
|
Service @15 psi drop (includes bypass and meter)
|
435 lpm (26.1 m3 /h) (115 GPM)
|
Backwash @ 25 psi drop (includes bypass)
|
303 lpm (18.2 m3 /h) (80 GPM)
|
Cv Service
|
29.7
|
Cv Backwash.
|
16
|
Operating Pressures
|
|
Minimum/Maximum
|
20 psi – 125 psi
|
Operating Temperatures
|
|
Minimum/Maximum
|
40º – 110º F
|
Meter
|
|
Accuracy
|
. ± 5%
|
Flow Rate Range.
|
. 2 – 284 lpm (0.5 – 75 gpm)
|
Gallon Range
|
. 0.02 – 5,700 m3
|
Totalizer
|
264 – 26,417,000 gallons
|
Dimensions & Weight
|
|
Distributor Pilot
|
1.050″ OD Pipe (¾” NPS)
|
Drain Line
|
1.5” Female NPT
|
Brine Line
|
1” Male NPT elbow
|
Mounting Base
|
4″ – 8 UN
|
Height From the Top Of the Tank
|
216 mm (8.5”)
|
Weight
|
29 lbs
|
Electrical Specifications
|
|
Supply Voltage
|
120V AC
|
Supply Frequency
|
60 Hz
|
Output Voltage
|
12V AC
|
Output Current
|
500 mA
|
Tank Applications
|
|
Water Softener
|
12” – 48” diameter
|
Water Filter (2)
|
12” – 36” diameter
|
Cycles of Operation (Softener / Filter downflow)
|
|
1. Backwash 1st
|
1-120
|
2. Rinse
|
1-120
|
3. Pause
|
1- 480
|
4. Brine
|
1-180
|
5. Refill Softener
|
0.1 – 99.0 minutes
|
6. Refill Filter
|
0.1 – 99.0 minutes
|
Reviews